♦ Minimum circulating volume: 0.2L/0.5L;
♦ Number of membrane tanks: 1/2 (different quantities can be customized);
♦ Membrane cell diameter: 4.5cm/8cm (other sizes can be customized);
♦ Working pressure: 0-1.5MPa;
♦ Working temperature: 5-55 ℃;
♦ PH range: 2-12 (depending on the membrane core);
♦ Material tank: 1.1L/1.1L+5L/1.1L+10 (can be customized according to the material);
1. The internal and external surface quality of the pipeline is excellent, and the entire set of equipment materials come into contact with the pipeline without any welding points, ensuring the pressure resistance and corrosion resistance of the equipment. The operation is simple, clean and hygienic, safe and reliable;
2. The equipment is controlled by dual pumps, and the microfiltration and ultrafiltration membranes can only start the auxiliary pump, effectively ensuring different control of flow and pressure during high and low pressure testing;
3. The pump adopts a pressure sensing system and a frequency conversion control system, which can adjust the pressure and flow rate through frequency conversion. It can set the ideal pressure and achieve automatic overpressure protection, making the use process very safe;
4. The membrane tank is designed as a square structure with a special flow channel design, which can ensure that the pressure and flow rate at each point of the membrane are stable and consistent;
5. Design according to fluid dynamics to ensure tangential flow and turbulence in the membrane pool, and ensure the reliability and stability of test data;
6. It can install microfiltration membranes, ultrafiltration membranes, nanofiltration membranes, and reverse osmosis membranes, suitable for membrane testing research and filtration experiments with small amounts of feed liquid;
7. Adopting a jacket material tank, it can be connected to a high and low temperature circulation device for temperature control;
8. The equipment is equipped with a digital pressure sensor with an accuracy of 0.4% FS, which can accurately record testing high and low pressure data, ensuring data accuracy and overcoming the defect of low accuracy of mechanical pressure gauges;
9. The equipment can set pressure and achieve automatic constant pressure control through a constant pressure control system to prevent automatic pressure increase during the testing process;
10. The equipment pressure and temperature are displayed digitally, and the sensor values are displayed in screen mode, which can be centrally displayed. If necessary, the data can be uploaded to the computer and recorded during the testing process;
11. Equipped with an overtemperature automatic protection system, with automatic alarm and shutdown for overtemperature;
One electromagnetic feed pump, one SUS316L membrane tank, one set of pressure sensors, one set of temperature sensors, one set of jacket material tanks, one pressure regulating valve, several pipelines and their connections, one set of rack, one set of overpressure control system, one set of overheating control system, and a unified set of data recording system.
Sterilization, clarification, and filtration of soy sauce, vinegar, etc
Removal of Impurities in Monosodium Glutamate Mother Liquor
Removal of impurities such as glucose crystallization mother liquor
Separation and purification of oligosaccharides and starch sugars
Fruit juice concentration and separation, plant extraction
Clarification and filtration of animal and plant extracts
Desalination and Concentration of Antibiotic Resin Analysis Solution
Vitamin concentration
Desalination concentration, replacing salting out and acid precipitation
Amino acids, decolorization and impurity removal, concentration, desalination
Complete multiple membrane equipment
Engineers with membrane engineering
Professional technical support provided
A comprehensive customer service system
Provide high-quality maintenance services